description: "## Tworzymy interfejs S5750E-52X-P-SI(config)#**int port-channel (nr_int)** ![](http://bazawiedzy/wp-content/uploads/2021/11/image-22.png) ## Przypisanie portchannelu do portu S5750E-52X-P-SI(config)#**int eth (nr_int)** S5750E-52X-P-SI(config-if-ethernet1/0/1**)#port-group (nr_portchannelu) mode active** ## Konfiguracja portchannelu S5750E-52X-P-SI(config)#**int port-channel (nr)** S5750E-52X-P-SI(config-if-port-channel2)#**switchport mode trunk** Set the port Port-Channel2 mode Trunk successfully S5750E-52X-P-SI(config-if-port-channel2)#**switchport trunk allowed vlan (nr_vlanów)**…"
url: "https://rioco.pl/docs/link-agregation-group/"
updated: "2024-09-14"
category: DCN
---

# DCN Link Agregation Group

## Tworzymy interfejs

S5750E-52X-P-SI(config)#**int port-channel (nr_int)**

![](http://bazawiedzy/wp-content/uploads/2021/11/image-22.png)

## Przypisanie portchannelu do portu

S5750E-52X-P-SI(config)#**int eth (nr_int)**

S5750E-52X-P-SI(config-if-ethernet1/0/1**)#port-group (nr_portchannelu) mode active**

## Konfiguracja portchannelu

S5750E-52X-P-SI(config)#**int port-channel (nr)**

S5750E-52X-P-SI(config-if-port-channel2)#**switchport mode trunk**

Set the port Port-Channel2 mode Trunk successfully

S5750E-52X-P-SI(config-if-port-channel2)#**switchport trunk allowed vlan (nr_vlanów)**

set the trunk port Port-Channel2 allowed vlan successfully.